Troubleshooting
Workflow Deployment Error
If there were any errors during the workflow deployment process, the Ingestion Pipeline Entity will still be created, but no workflow will be present in the Ingestion container.- You can then Edit the Ingestion Pipeline and Deploy it again.
- From the Connection tab, you can also Edit the Service if needed.
Connector Debug Troubleshooting
This section provides instructions to help resolve common issues encountered during connector setup and metadata ingestion in Collate. Below are some of the most frequently observed troubleshooting scenarios.How to Enable Debug Logging for Any Ingestion
To enable debug logging for any ingestion workflow in Collate:- Navigate to Services Go to Settings > Services > Service Type (e.g., Database) in the Collate UI.
- Select a Service Choose the specific service for which you want to enable debug logging.
- Access Agents Tab Go to the Agents tab and click the three-dot menu on the right-hand side of the ingestion type, and select Edit.
- Enable Debug Logging In the configuration dialog, enable the Debug Log option and click Next.
- Schedule and Submit Configure the schedule if needed and click Submit to apply the changes.
Permission Issues
If you encounter permission-related errors during connector setup or metadata ingestion, ensure that all the prerequisites and access configurations specified for each connector are properly implemented. Refer to the connector-specific documentation to verify the required permissions.Test Connection Fails on GetTables, Naming AWS Lake Formation
Test Connection can fail on the GetTables step with one of two distinct errors, both naming your catalog. Each has its own cause and remedy.No Schemas Were Available to Read
- The configured
schemaFilterPatternexcludes every database that exists. - The IAM principal used by the connector is missing the Glue/Athena permissions needed to list databases, or the Lake Formation Describe grant at the database level.
Resolution
- Review the configured
schemaFilterPatternand confirm it isn’t excluding every database in the catalog. - In IAM, confirm the principal used by the connector (a role, or an IAM user if the connector authenticates with an AWS access key) has the Glue/Athena list permissions from the connector’s required policy.
- In the AWS Lake Formation console, grant that principal Describe at the database level.
- Retry Test Connection.
No Tables Were Readable in Any Targeted Schema
Resolution
- In the AWS Lake Formation console, open Data permissions.
- Grant the IAM principal used by the Athena connector (a role, or an IAM user if the connector authenticates with an AWS access key) Describe and Select permissions on each database and table it needs to ingest.
- Re-run Test Connection. If the catalog genuinely has no tables yet, this failure is expected and can be ignored.